The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea

Jeong Geun Lee, Sang Hoon Byeon, Jai Hyo Lee

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Citations (Scopus)

Abstract

The effects of PSD for fine particles were investigated in subway train of Seoul. The permissible exposure limit(PEL) of fine particle, PM10, was 150 μg/m 3 in underground space. In this study, we found that average PM10 concentration showed over the PEL in subway platform. Average PM10 concentration in the platform not installed PSD was 1.4 times than that in the platform installed PSD. The PSD showed to improve the safety and environmental environments in subway train of Seoul. And PSD will be finished to install in all station of Seoul until this year (2009). Average PM10 concentration at platform of ground stations reduced about 29% than that of underground platform with PSD. And average PM2.5 concentration at platform of ground stations reduced about 55.7% than that of underground platform with PSD. Finally average PM1.0 concentration at platform of ground stations reduced about 51.0% than that of underground platform with PSD.

Original languageEnglish
Title of host publicationICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings
Pages1707-1710
Number of pages4
Publication statusPublished - 2009 Dec 1
EventICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009 - Fukuoka, Japan
Duration: 2009 Aug 182009 Aug 21

Publication series

NameICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings

Other

OtherICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009
CountryJapan
CityFukuoka
Period09/8/1809/8/21

Fingerprint

Subways

Keywords

  • Co
  • Platform screen door
  • PM10
  • Subway train

ASJC Scopus subject areas

  • Information Systems
  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering

Cite this

Lee, J. G., Byeon, S. H., & Lee, J. H. (2009). The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea. In ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings (pp. 1707-1710). [5334974] (ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings).

The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea. / Lee, Jeong Geun; Byeon, Sang Hoon; Lee, Jai Hyo.

ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. p. 1707-1710 5334974 (ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, JG, Byeon, SH & Lee, JH 2009, The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea. in ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings., 5334974, ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings, pp. 1707-1710, ICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009, Fukuoka, Japan, 09/8/18.
Lee JG, Byeon SH, Lee JH. The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea. In ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. p. 1707-1710. 5334974. (ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings).
Lee, Jeong Geun ; Byeon, Sang Hoon ; Lee, Jai Hyo. / The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea. ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. pp. 1707-1710 (ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings).
@inproceedings{e3cf00dba2fd4a218fe15451d66c2cbe,
title = "The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea",
abstract = "The effects of PSD for fine particles were investigated in subway train of Seoul. The permissible exposure limit(PEL) of fine particle, PM10, was 150 μg/m 3 in underground space. In this study, we found that average PM10 concentration showed over the PEL in subway platform. Average PM10 concentration in the platform not installed PSD was 1.4 times than that in the platform installed PSD. The PSD showed to improve the safety and environmental environments in subway train of Seoul. And PSD will be finished to install in all station of Seoul until this year (2009). Average PM10 concentration at platform of ground stations reduced about 29{\%} than that of underground platform with PSD. And average PM2.5 concentration at platform of ground stations reduced about 55.7{\%} than that of underground platform with PSD. Finally average PM1.0 concentration at platform of ground stations reduced about 51.0{\%} than that of underground platform with PSD.",
keywords = "Co, Platform screen door, PM10, Subway train",
author = "Lee, {Jeong Geun} and Byeon, {Sang Hoon} and Lee, {Jai Hyo}",
year = "2009",
month = "12",
day = "1",
language = "English",
isbn = "9784907764333",
series = "ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings",
pages = "1707--1710",
booktitle = "ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings",

}

TY - GEN

T1 - The effect of platform screen door (PSD) for fine particles at subway train in Seoul, Korea

AU - Lee, Jeong Geun

AU - Byeon, Sang Hoon

AU - Lee, Jai Hyo

PY - 2009/12/1

Y1 - 2009/12/1

N2 - The effects of PSD for fine particles were investigated in subway train of Seoul. The permissible exposure limit(PEL) of fine particle, PM10, was 150 μg/m 3 in underground space. In this study, we found that average PM10 concentration showed over the PEL in subway platform. Average PM10 concentration in the platform not installed PSD was 1.4 times than that in the platform installed PSD. The PSD showed to improve the safety and environmental environments in subway train of Seoul. And PSD will be finished to install in all station of Seoul until this year (2009). Average PM10 concentration at platform of ground stations reduced about 29% than that of underground platform with PSD. And average PM2.5 concentration at platform of ground stations reduced about 55.7% than that of underground platform with PSD. Finally average PM1.0 concentration at platform of ground stations reduced about 51.0% than that of underground platform with PSD.

AB - The effects of PSD for fine particles were investigated in subway train of Seoul. The permissible exposure limit(PEL) of fine particle, PM10, was 150 μg/m 3 in underground space. In this study, we found that average PM10 concentration showed over the PEL in subway platform. Average PM10 concentration in the platform not installed PSD was 1.4 times than that in the platform installed PSD. The PSD showed to improve the safety and environmental environments in subway train of Seoul. And PSD will be finished to install in all station of Seoul until this year (2009). Average PM10 concentration at platform of ground stations reduced about 29% than that of underground platform with PSD. And average PM2.5 concentration at platform of ground stations reduced about 55.7% than that of underground platform with PSD. Finally average PM1.0 concentration at platform of ground stations reduced about 51.0% than that of underground platform with PSD.

KW - Co

KW - Platform screen door

KW - PM10

KW - Subway train

UR - http://www.scopus.com/inward/record.url?scp=77951132992&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951132992&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9784907764333

T3 - ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings

SP - 1707

EP - 1710

BT - ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings

ER -