In this study, the feasibility of forward osmosis (FO) hybridized with membrane distillation (MD) was systematically investigated for treating flue gas desulfurization (FGD) wastewater. FO experiments were conducted using raw FGD wastewater obtained from a coal-fired power plant in Korea. Severe membrane fouling in FO was observed since FGD wastewater contained various components (i.e., particles, colloids, organics, and ions). The combined fouling layer by particulates and scales was identified via scanning electron microscope (SEM), energy dispersive X-ray (EDX) and X-ray diffraction (XRD). Therefore, fouling control strategies were suggested and evaluated. Microfiltration (MF) pre-treatment was effective in removing particulates and mitigating the initial fouling. Antiscalant-blended draw solution (DS) could inhibit the formation of membrane scaling. With such fouling control schemes, FO achieved the highest recovery rate compared to other desalting processes (i.e., RO and MD), suggesting that FO is suitable for treating wastewater with high fouling potential and high TDS. Finally, the diluted DS was recovered by MD. MD could re-concentrate the diluted DS up to 50% recovery rate with no significant flux decline. Rapid flux decline was then observed due to membrane scaling. Thus, appropriate antiscalants in DS should be considered to inhibit scaling formation in FO and MD simultaneously.

Original languageEnglish
Pages (from-to)44-51
Number of pages8
JournalChemosphere
Volume210
DOIs
Publication statusPublished - 2018 Nov 1

Fingerprint

Osmosis membranes
Coal
coal-fired power plant
Osmosis
Desulfurization
distillation
osmosis
Distillation
Power plants
Wastewater
Fouling
fouling
membrane
Membranes
wastewater
Flue gases
Fluxes
Salt removal
Recovery
Membrane fouling

Keywords

  • Flue gas desulfurization (FGD) wastewater
  • Forward osmosis (FO)
  • Industrial wastewater treatment
  • Membrane distillation (MD)
  • Membrane fouling control

ASJC Scopus subject areas

  • Chemistry(all)
  • Environmental Chemistry

Cite this

Treatment of industrial wastewater produced by desulfurization process in a coal-fired power plant via FO-MD hybrid process. / Lee, Songbok; Kim, Youngjin; Hong, Seungkwan.

In: Chemosphere, Vol. 210, 01.11.2018, p. 44-51.

Research output: Contribution to journalArticle

@article{84401f77932541ffaf8c155727900ee5,
title = "Treatment of industrial wastewater produced by desulfurization process in a coal-fired power plant via FO-MD hybrid process",
abstract = "In this study, the feasibility of forward osmosis (FO) hybridized with membrane distillation (MD) was systematically investigated for treating flue gas desulfurization (FGD) wastewater. FO experiments were conducted using raw FGD wastewater obtained from a coal-fired power plant in Korea. Severe membrane fouling in FO was observed since FGD wastewater contained various components (i.e., particles, colloids, organics, and ions). The combined fouling layer by particulates and scales was identified via scanning electron microscope (SEM), energy dispersive X-ray (EDX) and X-ray diffraction (XRD). Therefore, fouling control strategies were suggested and evaluated. Microfiltration (MF) pre-treatment was effective in removing particulates and mitigating the initial fouling. Antiscalant-blended draw solution (DS) could inhibit the formation of membrane scaling. With such fouling control schemes, FO achieved the highest recovery rate compared to other desalting processes (i.e., RO and MD), suggesting that FO is suitable for treating wastewater with high fouling potential and high TDS. Finally, the diluted DS was recovered by MD. MD could re-concentrate the diluted DS up to 50{\%} recovery rate with no significant flux decline. Rapid flux decline was then observed due to membrane scaling. Thus, appropriate antiscalants in DS should be considered to inhibit scaling formation in FO and MD simultaneously.",
keywords = "Flue gas desulfurization (FGD) wastewater, Forward osmosis (FO), Industrial wastewater treatment, Membrane distillation (MD), Membrane fouling control",
author = "Songbok Lee and Youngjin Kim and Seungkwan Hong",
year = "2018",
month = "11",
day = "1",
doi = "10.1016/j.chemosphere.2018.06.180",
language = "English",
volume = "210",
pages = "44--51",
journal = "Chemosphere",
issn = "0045-6535",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Treatment of industrial wastewater produced by desulfurization process in a coal-fired power plant via FO-MD hybrid process

AU - Lee, Songbok

AU - Kim, Youngjin

AU - Hong, Seungkwan

PY - 2018/11/1

Y1 - 2018/11/1

N2 - In this study, the feasibility of forward osmosis (FO) hybridized with membrane distillation (MD) was systematically investigated for treating flue gas desulfurization (FGD) wastewater. FO experiments were conducted using raw FGD wastewater obtained from a coal-fired power plant in Korea. Severe membrane fouling in FO was observed since FGD wastewater contained various components (i.e., particles, colloids, organics, and ions). The combined fouling layer by particulates and scales was identified via scanning electron microscope (SEM), energy dispersive X-ray (EDX) and X-ray diffraction (XRD). Therefore, fouling control strategies were suggested and evaluated. Microfiltration (MF) pre-treatment was effective in removing particulates and mitigating the initial fouling. Antiscalant-blended draw solution (DS) could inhibit the formation of membrane scaling. With such fouling control schemes, FO achieved the highest recovery rate compared to other desalting processes (i.e., RO and MD), suggesting that FO is suitable for treating wastewater with high fouling potential and high TDS. Finally, the diluted DS was recovered by MD. MD could re-concentrate the diluted DS up to 50% recovery rate with no significant flux decline. Rapid flux decline was then observed due to membrane scaling. Thus, appropriate antiscalants in DS should be considered to inhibit scaling formation in FO and MD simultaneously.

AB - In this study, the feasibility of forward osmosis (FO) hybridized with membrane distillation (MD) was systematically investigated for treating flue gas desulfurization (FGD) wastewater. FO experiments were conducted using raw FGD wastewater obtained from a coal-fired power plant in Korea. Severe membrane fouling in FO was observed since FGD wastewater contained various components (i.e., particles, colloids, organics, and ions). The combined fouling layer by particulates and scales was identified via scanning electron microscope (SEM), energy dispersive X-ray (EDX) and X-ray diffraction (XRD). Therefore, fouling control strategies were suggested and evaluated. Microfiltration (MF) pre-treatment was effective in removing particulates and mitigating the initial fouling. Antiscalant-blended draw solution (DS) could inhibit the formation of membrane scaling. With such fouling control schemes, FO achieved the highest recovery rate compared to other desalting processes (i.e., RO and MD), suggesting that FO is suitable for treating wastewater with high fouling potential and high TDS. Finally, the diluted DS was recovered by MD. MD could re-concentrate the diluted DS up to 50% recovery rate with no significant flux decline. Rapid flux decline was then observed due to membrane scaling. Thus, appropriate antiscalants in DS should be considered to inhibit scaling formation in FO and MD simultaneously.

KW - Flue gas desulfurization (FGD) wastewater

KW - Forward osmosis (FO)

KW - Industrial wastewater treatment

KW - Membrane distillation (MD)

KW - Membrane fouling control

UR - http://www.scopus.com/inward/record.url?scp=85049999805&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049999805&partnerID=8YFLogxK

U2 - 10.1016/j.chemosphere.2018.06.180

DO - 10.1016/j.chemosphere.2018.06.180

M3 - Article

C2 - 29986222

AN - SCOPUS:85049999805

VL - 210

SP - 44

EP - 51

JO - Chemosphere

JF - Chemosphere

SN - 0045-6535

ER -