Two-level multi-pinhole collimator for SPECT imaging using a small-field-of-view gamma camera

Jaekeon Bae, Seungbin Bae, Soo young Lee, Kisung Lee, Yongkwon Kim, Jinhun Joung, Min Ho Kim, Kyeong Min Kim

Research output: Contribution to journalArticle

Abstract

The aim of this study was to develop a high-throughput imaging method for single-photon emission computed tomography. We developed a target-oriented multi-pinhole collimator and limitedangle method for scanning small organs such as the thyroid. To maximize the resolution and the sensitivity of the collimator, we designed a two-level multi-pinhole collimator whose levels were optimized for concave body contours. One level had a center hole whereas the other had surrounding holes. The limited-angle scanning method was employed to obtain tomographic images by using the collimator located near the body contour of the target, and a corresponding image reconstruction algorithm was implemented. A small-field-of-view gamma camera was used to achieve a smaller footprint. The design of the collimator also considered the dimensions of used gamma camera. Evaluation studies were conducted using the Geant4 application for tomographic emission. The results showed the resolution of the proposed collimator to be more than twice that of the previously designed multi-pinhole collimator while maintaining the same efficiency. Given that the designed collimator can be changed by simply replacing the center hole, the suggested imaging method is suitable for studying not only the thyroid but also any organ whose diameter is less than 90 mm.

Original languageEnglish
Pages (from-to)192-200
Number of pages9
JournalJournal of the Korean Physical Society
Volume70
Issue number2
DOIs
Publication statusPublished - 2017 Jan 1

Fingerprint

pinholes
collimators
field of view
cameras
organs
scanning
footprints
image reconstruction
tomography
evaluation
sensitivity
photons

Keywords

  • Image reconstruction
  • Limited-angle reconstruction
  • Multi-pinhole collimator
  • Organ-specific application
  • Single-photon emission computed tomography
  • Target oriented system

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Two-level multi-pinhole collimator for SPECT imaging using a small-field-of-view gamma camera. / Bae, Jaekeon; Bae, Seungbin; Lee, Soo young; Lee, Kisung; Kim, Yongkwon; Joung, Jinhun; Kim, Min Ho; Kim, Kyeong Min.

In: Journal of the Korean Physical Society, Vol. 70, No. 2, 01.01.2017, p. 192-200.

Research output: Contribution to journalArticle

Bae, Jaekeon ; Bae, Seungbin ; Lee, Soo young ; Lee, Kisung ; Kim, Yongkwon ; Joung, Jinhun ; Kim, Min Ho ; Kim, Kyeong Min. / Two-level multi-pinhole collimator for SPECT imaging using a small-field-of-view gamma camera. In: Journal of the Korean Physical Society. 2017 ; Vol. 70, No. 2. pp. 192-200.
@article{6cbc00659b8248db9345a556b13bf058,
title = "Two-level multi-pinhole collimator for SPECT imaging using a small-field-of-view gamma camera",
abstract = "The aim of this study was to develop a high-throughput imaging method for single-photon emission computed tomography. We developed a target-oriented multi-pinhole collimator and limitedangle method for scanning small organs such as the thyroid. To maximize the resolution and the sensitivity of the collimator, we designed a two-level multi-pinhole collimator whose levels were optimized for concave body contours. One level had a center hole whereas the other had surrounding holes. The limited-angle scanning method was employed to obtain tomographic images by using the collimator located near the body contour of the target, and a corresponding image reconstruction algorithm was implemented. A small-field-of-view gamma camera was used to achieve a smaller footprint. The design of the collimator also considered the dimensions of used gamma camera. Evaluation studies were conducted using the Geant4 application for tomographic emission. The results showed the resolution of the proposed collimator to be more than twice that of the previously designed multi-pinhole collimator while maintaining the same efficiency. Given that the designed collimator can be changed by simply replacing the center hole, the suggested imaging method is suitable for studying not only the thyroid but also any organ whose diameter is less than 90 mm.",
keywords = "Image reconstruction, Limited-angle reconstruction, Multi-pinhole collimator, Organ-specific application, Single-photon emission computed tomography, Target oriented system",
author = "Jaekeon Bae and Seungbin Bae and Lee, {Soo young} and Kisung Lee and Yongkwon Kim and Jinhun Joung and Kim, {Min Ho} and Kim, {Kyeong Min}",
year = "2017",
month = "1",
day = "1",
doi = "10.3938/jkps.70.192",
language = "English",
volume = "70",
pages = "192--200",
journal = "Journal of the Korean Physical Society",
issn = "0374-4884",
publisher = "Korean Physical Society",
number = "2",

}

TY - JOUR

T1 - Two-level multi-pinhole collimator for SPECT imaging using a small-field-of-view gamma camera

AU - Bae, Jaekeon

AU - Bae, Seungbin

AU - Lee, Soo young

AU - Lee, Kisung

AU - Kim, Yongkwon

AU - Joung, Jinhun

AU - Kim, Min Ho

AU - Kim, Kyeong Min

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The aim of this study was to develop a high-throughput imaging method for single-photon emission computed tomography. We developed a target-oriented multi-pinhole collimator and limitedangle method for scanning small organs such as the thyroid. To maximize the resolution and the sensitivity of the collimator, we designed a two-level multi-pinhole collimator whose levels were optimized for concave body contours. One level had a center hole whereas the other had surrounding holes. The limited-angle scanning method was employed to obtain tomographic images by using the collimator located near the body contour of the target, and a corresponding image reconstruction algorithm was implemented. A small-field-of-view gamma camera was used to achieve a smaller footprint. The design of the collimator also considered the dimensions of used gamma camera. Evaluation studies were conducted using the Geant4 application for tomographic emission. The results showed the resolution of the proposed collimator to be more than twice that of the previously designed multi-pinhole collimator while maintaining the same efficiency. Given that the designed collimator can be changed by simply replacing the center hole, the suggested imaging method is suitable for studying not only the thyroid but also any organ whose diameter is less than 90 mm.

AB - The aim of this study was to develop a high-throughput imaging method for single-photon emission computed tomography. We developed a target-oriented multi-pinhole collimator and limitedangle method for scanning small organs such as the thyroid. To maximize the resolution and the sensitivity of the collimator, we designed a two-level multi-pinhole collimator whose levels were optimized for concave body contours. One level had a center hole whereas the other had surrounding holes. The limited-angle scanning method was employed to obtain tomographic images by using the collimator located near the body contour of the target, and a corresponding image reconstruction algorithm was implemented. A small-field-of-view gamma camera was used to achieve a smaller footprint. The design of the collimator also considered the dimensions of used gamma camera. Evaluation studies were conducted using the Geant4 application for tomographic emission. The results showed the resolution of the proposed collimator to be more than twice that of the previously designed multi-pinhole collimator while maintaining the same efficiency. Given that the designed collimator can be changed by simply replacing the center hole, the suggested imaging method is suitable for studying not only the thyroid but also any organ whose diameter is less than 90 mm.

KW - Image reconstruction

KW - Limited-angle reconstruction

KW - Multi-pinhole collimator

KW - Organ-specific application

KW - Single-photon emission computed tomography

KW - Target oriented system

UR - http://www.scopus.com/inward/record.url?scp=85010866484&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85010866484&partnerID=8YFLogxK

U2 - 10.3938/jkps.70.192

DO - 10.3938/jkps.70.192

M3 - Article

VL - 70

SP - 192

EP - 200

JO - Journal of the Korean Physical Society

JF - Journal of the Korean Physical Society

SN - 0374-4884

IS - 2

ER -