Usefulness of standard deviation on the histogram of ultrasound as a quantitative value for hepatic parenchymal echo texture; preliminary study

Chang Hee Lee, Jae Woong Choi, Kyeong Ah Kim, Tae Seok Seo, Jong Mee Lee, Cheol Min Park

    Research output: Contribution to journalArticlepeer-review

    41 Citations (Scopus)

    Abstract

    This study examined whether the standard deviation (SD) values on the histogram measured in the picture archiving and communication system (PACS) views of an ultrasound (US) can be used as an index to determine the homogeneity or heterogeneity of a hepatic parenchymal echo. Patients (n = 202) underwent an abdominal US examination. One US unit was used with a convex (3 to 5 MHz) transducer. The echogenicity of the hepatic parenchyma was measured in four different regions-of-interest (ROIs) of the liver with all vessels, bile ducts and calcification being avoided. The SDs were calculated automatically on the histogram of the ROI in the PACS views. The echo patterns of the liver were classified into normal, fatty liver (FL) and chronic liver disease (CLD). The distribution of the SD calculated from the ROI histogram of these three groups was examined, and statistical analysis for multiple comparisons of the average SD of the three groups was carried out using one-way analysis of variance. Among the 202 patients, there were 72 normal patients (mean SD: 11.10 ± 0.91), 66 with a FL (mean SD: 11.09 ± 1.04) and 64 with CLD (mean SD: 14.21 ± 2.32). The SD values of the normal and FL groups were similar (p > 0.05), but there were significant differences (p < 0.0001) between the CLD and normal groups, and between the CLD and FL groups. The SD values of the abdominal US examination, which had been calculated on the ROI histogram of the PACS view, are believed to reflect the homogeneity or heterogeneity of the hepatic parenchyma. Smaller SD values are thought to represent normal or FL conditions, and larger SD values reflect the possibility of CLD that shows coarse echo. Therefore, it is concluded that the SD can be used as a useful quantitative value that can determine the coarseness of CLD. (E-mail: chlee86@hanmail.net).

    Original languageEnglish
    Pages (from-to)1817-1826
    Number of pages10
    JournalUltrasound in Medicine and Biology
    Volume32
    Issue number12
    DOIs
    Publication statusPublished - 2006 Dec

    Keywords

    • Echogenicity
    • Liver
    • Tissue characterization
    • Ultrasound

    ASJC Scopus subject areas

    • Biophysics
    • Radiological and Ultrasound Technology
    • Acoustics and Ultrasonics

    Fingerprint

    Dive into the research topics of 'Usefulness of standard deviation on the histogram of ultrasound as a quantitative value for hepatic parenchymal echo texture; preliminary study'. Together they form a unique fingerprint.

    Cite this